TM5SAI4PH Analog Input Module

TM5SAI4PH Analog Input Module

SKU: TM5SAI4PH
$700.00
$775.00
Add To Cart
In Stock - Limited Qty
QTY Available:10+
Brand: Schneider Electric
Package: 1

Analog Input Module - 4I -Temperature Probe PT100/PT1000 - 16 bits

Description

Main
range of product
Modicon TM5
product or component type
Analog input module
analogue input number
4
analogue input type
Pt 100/Pt 1000 temperature probe - 200...850 °C
analogue input resolution
16 bits
Complementary
range compatibility
Modicon LMC058
Modicon M258
product compatibility
Logic controller
Motion controller
measurement resolution
0.1 °C
color
White
measurement error
< 0.037 % of full scale - 200...850 °C Pt 100/Pt 1000 25 °C
temperature coefficient
0.004 %FS/°C temperature probe
non-linearity
0.001 %FS temperature probe
type of cable
Shielded cable
isolation
No insulation between channels
500 Vrms AC insulation between channel and bus
supply
Internal
[Us] rated supply voltage
24 V DC -15...20 %
common mode rejection
> 95 dB
local signalling
1 LED green power supply
1 LED red power supply
4 LEDs green input status
current consumption
2 mA 5 V DC bus
46 mA 24 V DC input/output
maximum power dissipation in W
1.11 W
marking
CE
Net Weight
0.06 lb(US) (0.025 kg)
Environment
standards
UL 508
CSA C22.2 No 213
IEC 61131-2
CSA C22.2 No 142
product certifications
GOST-R
CSA
C-tick
CULus
ambient air temperature for operation
32…131 °F (0…55 °C) without derating horizontal installation)
32…140 °F (0…60 °C) with derating factor horizontal installation)
32…122 °F (0…50 °C) vertical installation)
ambient air temperature for storage
-13…158 °F (-25…70 °C)
relative humidity
5…95 % without condensation
IP degree of protection
IP20IEC 61131-2
pollution degree
2 IEC 60664
operating altitude
0...6561.68 ft (0...2000 m)
storage altitude
0.00…9842.52 ft (0…3000 m)
vibration resistance
1 gn at 8.4…150 Hz on DIN rail
3.5 mm at 5…8.4 Hz on DIN rail
shock resistance
15 gn for 11 ms
resistance to electrostatic discharge
4 kV on contact EN/IEC 61000-4-2
8 kV in air EN/IEC 61000-4-2
resistance to electromagnetic fields
1 V/m 2...2.7 GHz conforming to EN/IEC 61000-4-3
10 V/m 80...2000 MHz conforming to EN/IEC 61000-4-3
resistance to fast transients
1 kV (I/O) conforming to EN/IEC 61000-4-4
1 kV EN/IEC 61000-4-4 shielded cable)
2 kV (power lines) conforming to EN/IEC 61000-4-4
surge withstand
0.5 kV differential mode conforming to EN/IEC 61000-4-5
1 kV common mode conforming to EN/IEC 61000-4-5
electromagnetic compatibility
EN/IEC 61000-4-6
disturbance radiated/conducted
CISPR 11